For homes and businesses; with integrated energy meters, up to 11 kW.
| Electrical specifications | |
|---|---|
| Power | 11 kW |
| Rated current | 16 A |
| Grid voltage | 220-240 V / 380-415 V |
| Grid frequency | 50/60 Hz |
| Vehicle charging connector | Type 2 |
| Charging power mode 3 | 11 kW |
| Charging current mode 3 | 3×16 A |
| Grid connection | L1, L2, L3, N, PE |
| Earthing system | TT/TN 3- and 1-phase, IT 1-phase |
| Overvoltage category | III |
| Protection class | I |
| Integrated DC residual current device | 6 mA |
| Technical features | |
| Vehicle communication | PWM (according to IEC61851) |
| Cable length | 7 m |
| Variant with type 2 socket / type 2 socket with shutter | / |
| HMI | RGB LEDs, buzzer, web app |
| Identification | – RFID – Plug & Charge (ISO 15118) – Autocharge |
| Network connection | – LAN (RJ45) – 10 / 100 Base-TX – WiFi (5 GHz, 2.4 GHz) – WiFi client / hotspot (possible at the same time) |
| Back-end communication | OCPP 1.6j (2.0.1 in development) |
| Integration with home energy management system (HEMS) | EEBUS, Modbus for external energy meters |
| Consumption measurement | Integrated |
| Local load management | via WLAN, Ethernet |
| Environmental specifications | |
| IP protection class | IP55 |
| IK protection class | IK10 |
| Dimensions | 384 x 384 x 181 mm |
| Weight | approx. 3.15 kg (without cable) |
| Operating temperature | -30 °C – +45 °C |
| Storage temperature | -40 °C – +80 °C |
| Altitude | ≤ 3,000 m |